Wear can damage the pump on Graco Ultra and UltraMax Airless equipment. As an error message, the red light below the pressure control illuminates four times after the trigger has been removed – for example when the pump is blocked. In this case, the pump has reached its lifetime and should be replaced. In the video, the steps to repair the pump of the Graco Ultra and UltraMax are explained in detail.

 

Order Graco Ultra Pump

To order a replacement pump, simply choose from the list below:

  • Order Graco Triax replacement pump for Graco Ultra directly from the cable – click here
  • Order Graco Triax replacement pump for Graco Ultra with battery directly – click here
  • Order Graco Triax replacement pump for Graco UltraMax directly – click here

Step-by-step instructions for repairing the Graco Ultra & UltraMax pump

  1. Disconnect power supply (battery / cable) and turn the spray / prime nub down to the prime position
  2. Remove the cup assembly
  3. Remove the tip guard assembly and turn the prime / spray nub forward to the spray position
  4. Remove the cross-head screw from the prime / pump spray nub and remove the nub
  5. Remove the seven cross-head screws from the sprayer enclosure and remove the enclosure cover
  6. Carefully remove the pump assembly from the enclosure (on the Graco UltraMax you will have to remove the static dissipation wire first – and save the screw!)
  7. Place the new pump assembly into the Smart Control housing – DO NOT REMOVE THE YELLOW LOCKING DEVICE! (on Graco UltraMax models you will have to reinstall the static dissipation wire) 
  8. Push the pump assembly down into the SmartControl enclosure – the pump locking device will snap away from the pump assembly
  9. Install the enclosure cover and install the cross-head screws, making sure the wires are not pinched. See the manual for correct torque specifications
  10. You will need to install the prime / spray nub so the nub is pointing forward. Install the cross-head screw at the back of the nub. Make sure the prime / pump nub only rotates forward and down
  11. Attach the tip guard assembly and the cup assembly
  12. Verify the prime / pump nub has been properly installed by turning it forward to the spray position and down to the prime position
  13. Fill the cup assembly with water and test spraying

Safety Note: To repair and replace the pump unit of the Graco Ultra and Graco UltraMax, disconnect the sprayer from the power supply (battery, cable). In addition, the pressure should be released via the relief valve. In addition, please observe the operating and repair instructions of the manufacturer.

More information on the Graco Ultra and Graco Ultra Max

For more information about Graco Ultra & UltraMax, we have summarized for you in the following posts:

Safety note: The instructions in the operating instructions should be taken into account in the above-mentioned measures for fault elimination. In addition, the sprayer should be disconnected from the power supply (cable or battery) and the unit should not be under pressure (depressurize).

Love our content? You can find more here:

Visit our Facebook page

Check out our Airless Discounter YouTube channel

Airless Discounter Instagram account

Questions or queries?

For any further questions or if you would like to get your hands on one of these products seen in this article, you can contact us on +49 (0) 30 220 15436, fill out our contact form or email us. If you wish to purchase one of the products mentioned above, you can check them out in our online store. You can also visit us at our service base during office hours.